CT Scanners

iCT

CT Scanner

Product number:

NCTC613

Built upon our latest advances in reconstruction techniques, workflow, and detector technologies, the iCT is designed to redefine CT imaging.

Contact information

* This field is mandatory
*

Contact details

*
*
*

Company details

*
*
*
*
*

Business details

By specifying your reason for contact we will be able to provide you with a better service.
*
*
Features
IMR || Industry-leading low-contrast

IMR - industry-leading low-contrast resolution

With Philips IMR you can simultaneously achieve 60–80% lower dose, 43–80% improved low-contrast detectability, and 70–83% lower noise.* IMR gives you confidence through enhanced visualization of fine detail.
iPatient || Confidence and consistency

iPatient for scan-to-scan consistency

Philips iPatient is an advanced platform that puts you in control of enhancing your CT system today, while getting you ready for the challenges of tomorrow. This allows you to plan the results, not the acquisition. It also gives you confidence and consistency 24/7.
iDose⁴ Premium Package || High image quality with reduce

iDose⁴ Premium Package reduces noise and artifacts

iDose⁴ improves image quality** through artifact prevention and increased spatial resolution at low dose. O-MAR reduces artifacts caused by large orthopedic implants. Together they produce high image quality with reduced artifacts.
NanoPanel Elite || Low-noise and low-energy and l

NanoPanel Elite detector technology reduces image noise

The NanoPanel Elite detector uses direct integration technology to reduce image noise at low energy and low dose. Its miniaturization and integration capabilities provide a low-noise, high-fidelity signal which results in a marked image noise improvement.
iPatient || Confidence and consistency

iPatient for scan-to-scan consistency

Philips iPatient is an advanced platform that puts you in control of enhancing your CT system today, while getting you ready for the challenges of tomorrow. This allows you to plan the results, not the acquisition. It also gives you confidence and consistency 24/7.
  • *In clinical practice, the use of IMR may reduce CT patient dose depending on the clinical task, patient size, anatomical location, and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. Lower image noise, improved spatial resolution, improved low-contrast detectability, and/or dose reduction, were tested using reference body protocols. All metrics were tested on phantoms. Dose reduction assessments were performed using 0.8 mm slices, and tested on the MITA CT IQ Phantom (CCT183, The Phantom Laboratory), using human observers. Data on file.
  • ** Improved image quality as defined by improvements in spatial resolution and/or noise reduction as measured in phantom studies.