Imaging Systems

Ingenia 3.0T

MR system

Find similar products

At the forefront of clinical excellence -- Diagnostic confidence, explore advanced applications, and generate the productivity required to meet today’s healthcare challenges with the Ingenia 3.0T. Through dStream, Ingenia delivers premium image quality with digital clarity and speed –and with iPatient, it provides patient-centric imaging, from patient set-up to image result.

Specifications

Xtend Magnet System
Xtend Magnet System
Open bore diameter
  • 70 cm
Magnet weight
  • 4600 kg
Maximum FOV
  • 55 cm
Typical homogeneity at 50 x 50 x 45 cm
  • ≤ 1.1 ppm
Typical homogeneity at 55x55x50 cm
  • ≤ 5 ppm
Typical homogeneity at 45 cm DSV -
  • ≤ 1.1 ppm
HeliumSave technology
  • (Zero boil-off) Yes
Cryogen boil-off rate under regular scanning conditions
  • 0 l/hr
Cryogen boil-off rate
  • 0 l/hr***
Xtend Gradient - 3.0T Omega HP
Xtend Gradient - 3.0T Omega HP
Max. amplitude for each axis
  • 45 mT/m
Max. slew rate for each axis
  • 200 T/m/s
Omega HP gradients
Omega HP gradients
Max. amplitude for each axis
  • 45 mT/m
Max. slew rate for each axis
  • 200 T/m/s
Resolution parameters
Resolution parameters
Max scan matrix
  • 1024 (2048 optional)
Max. number of slices
  • 1024
Highest in-plane resolution
  • 5 µm
Resolution Parameters - 3.0T Omega HP
Resolution Parameters - 3.0T Omega HP
Max scan matrix
  • 1024 (2048 optional)
Highest in-plane resolution
  • 5 µm
RF Transmit
RF Transmit
Parallel RF transmission
  • Yes, MultiTransmit
RF control
  • Inside the coil
Number of independent RF amplifiers
  • 2
Output power
  • 2 × 18 kW
dStream RF Receive
dStream RF Receive
Number of independent receive channels
  • Digital signal chain from coil electronics to connector
Signal chain from coil to reconstructor
  • Channel Independent
  • Digital signal chain from connector to magnet
  • Digital signal chain from magnet to reconstructor
Number of independent receive channels
  • Channel independent
Location of analog-to-digital converter (ADC)
  • Patient-adaptive. Fully flexible for each source, real time feedback loop
Location of analog-to-digital converter (ADC)
  • Inside the coil
Signal chain from coil to reconstructor
  • Fully digital
Signal chain from coil electronics to connector
  • Digital
Signal chain from connector to magnet
  • Digital
Signal chain from magnet to reconstructor
  • Digital
Patient environment
Patient environment
Bore design
  • 70 cm
Patient aperture
  • 70 cm
Flare on both ends
  • Yes
Flare on both ends
  • Yes
Tunnel diameter at both ends
  • 95 cm
Tunnel diameter at both ends
  • 95 cm
Maximum weight capacity
  • 250 kg (550 lbs)
Maximum weight capacity****
  • 250 kg (550 lbs)
Patient transport system (optional)
  • FlexTrak
Patient transport system
  • FlexTrak
Patient transport system (optional)
  • FlexTrak Mammo
Wireless patient physiological synchronization
  • Yes
Wireless patient physiological synchronization
  • Yes
Various acoustic noise reduction solutions
  • Yes
Various acoustic noise reduction solutions
  • Yes
Site Planning
Site Planning
Total gantry installed weight
  • ≤ 5800 kg
Minimum siting requirement
  • 30 m²
dStream Workflow
dStream Workflow
FlexCoverage posterior coil
  • Yes
FlexCoverage Posterior coil
  • Yes
FlexCoverage Anterior coils (optional)
  • Yes
FlexCoverage anterior coil (optional)
  • Yes
FlexConnect connectors
  • Yes
FlexConnect connectors
  • Yes
FlexTrak tabletop
  • Yes
FlexTrak tabletop
  • Yes
FlexCaddy coil storage (optional)
  • Yes
FlexCaddy coil storage (optional)
  • Yes
FlexTrak patient transport system (optional)
  • Yes
FlexTrak patient transport system (optional)
  • Yes
FlexTrak Mammo mammography solution (optional)
  • Yes
FlexTrak Mammo mammography solution (optional)
  • Yes
iPatient efficiency assistance
iPatient efficiency assistance
SmartStart
  • Yes
SmartSelect
  • Yes
SmartExam (optional)
  • Yes
SmartLine (package dependent)
  • Yes
SmartLink (package dependent)
  • Yes
Efficiency Assistance with iPatient
Efficiency Assistance with iPatient
SmartStart
  • Yes
SmartSelect
  • Yes
SmartExam (optional)
  • Yes
SmartLine (package dependent)
  • Yes
SmartLink (package dependent)
  • Yes
  • * Cryogen boil-off rate under regular conditions
  • ** For vertical and horizontal movement
  • ¹ “2014 Top 20 Best in KLAS Awards: 2014 Best in KLAS Awards: Medical Equipment & Infrastructure,” July, 2014. © 2014 KLAS Enterprises, LLC. All rights reserved. www.KLASresearch.com